electrophoresis

vertical electrophoresis

The versatile, easy-to-use Mini-PROTEAN Tetra vertical electrophoresis cell is ideal for protein electrophoresis with Bio-Rad precast polyacrylamide mini gels.

2-gel

Specification:

Number of gels – 1–2
Cell (tank and lid with power cables) – 1
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Total buffer volume for 2 gels, ml – 800
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

2-gel, for 0.75 mm thick handcast gels

Specification:

Number of gels – 1–2
Cell (tank and lid with power cables) – 1
10-well combs -5
0.75 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stands – 1
Casting frames – 2
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml- 800
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

2-gel, for 1.0 mm thick handcast gels

Specification:

Number of gels – 1–2
Cell (tank and lid with power cables) – 1
10-well combs – 5
1.0 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stands – 2
Casting frames- 4
Precast gels- Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml – 800
Recommended power supply- PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam- 1

2-gel, for 1.5 mm thick handcast gels

Specification:

Number of gels – 1–2
Cell (tank and lid with power cables) – 1
10-well combs – 5
1.5 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stands- 1
Casting frames – 2
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml – 800
Total buffer volume for 4 gels, ml – 1,000
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

4-gel

Specification:

Number of gels – 1–4
Cell (tank and lid with power cables) – 1
Companion module (to run up to 4 gels) – 1
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Total buffer volume for 2 gels, ml – 800
Total buffer volume for 4 gels, ml – 1,000
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

4-gel, for 0.75 mm thick handcast gels

Specification:

Number of gels – 1–4
Cell (tank and lid with power cables) – 1
Companion module (to run up to 4 gels) – 1
10-well combs – 5
0.75 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stands – 2
Casting frames – 4
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml – 800
Total buffer volume for 4 gels, ml – 1,000
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

4-gel, for 1.0 mm thick handcast gels

Specification:

Number of gels – 1–4
Cell (tank and lid with power cables) – 1
Companion module (to run up to 4 gels) – 1
10-well combs – 5
1.0 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stands – 2
Casting frames – 4
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml – 800
Total buffer volume for 4 gels, ml – 1,000
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam – 1

4-gel, for 1.5 mm thick handcast gels

Specification:

Number of gels – 1–4
Cell (tank and lid with power cables) – 1
Companion module (to run up to 4 gels) – 1
10-well combs – 5
1.5 mm spacer plates (5 plates per box) – 1 box
Short plates (5 plates per box) – 1 box
Casting stand – 2
Casting frames – 4
Precast gels – Mini-PROTEAN or Ready Gel® precast gels
Handcast gels – Handcast using Mini-PROTEAN glass plates
Total buffer volume for 2 gels, ml – 800
Total buffer volume for 4 gels, ml – 1,000
Recommended power supply – PowerPac™ Basic, PowerPac HC (high current), PowerPac HV (high voltage), or PowerPac Universal
Typical run time for SDS-PAGE – 35–45 min (at 200 V constant)
Gel format – Mini
Buffer dam -1