D-2, Anand Apartments, No. 72/3, Nehru 100 Feet Road ,Vadapalani, Chennai-600026,

Email us

leadsindiasai@gmail.com

Call us

+91-9942987603

Meter

TDS Meter

Digital Conductivity Meter 304 and 307 are convenient instrument for routine measurements of conductivity of various electrolytes such as Caustic content of rinse water, Electrolytic impurities in Distilled / Demineralised water, Sulphuric Acid concentration in pickling baths, Anodizing tanks, Soil Conductivity and other applications. The instrument uses state of the art IC technology and consumes very little power. Source frequency (100 Hz or 1 KHz) gets automatically selected in the appropriate range. Type 307 also measures Total Dissolved Solid (TDS) in liquid. The unit is housed in compact, shock/rust proof & light weight injection molded cabinet.

Specification :

  • Manual instrument, convenient for routine analysis
  • Cond. Range : 0 µS – 20 mS with 0.1 cell, 0 µS – 200 mS with 1 cell
  • Cond. Resolution : 0.01µS
  • TDS Range :0 ppm – 20 ppt with 0.1 cell, 0 ppm – 200 ppt with 1 cell
  • TDS Resolution : 0.01 ppm
  • Temperature : 00 C – 1000 C (Auto / Manual)
  • Readout : 3 digits LED

Model 304

Specification :

  • Source Frequency   – 100Hz or 1KHz automatically selected
  • Conductivity Range – 0 pS to 200 mS with 1.0 cell constant (5 decadic ranges)
  • TDS
  • Temperature -0° C to 100° C (Manual)
  • Display – 3 digits LED
  • Resolution
    Conductivity
    TDS
    Temperature -0.1ps
  • Accuracy
    Conductivity / TDS
    Temperature – +1% of f.s. z1 digit (Conductivity )
  • Cond.Celt Compensation
    0.1 Cell Constant
    1 Cell Constant -0.9 to 1.1
  • TDS – Factor
    Cond. Tempco Range –
  • Temperature Range
  • Temperature Sensor
  • Power – 230 V +10% 50 Hz
  • Dimensions – 235(W) X 185(D) X 85(H) mm
  • Weight – 1.25 kg (Approx)
  • Accessories                              -(1) 1 Cell Constant Cell
    (2) Clamp & Stand

Model 306

Specification :

  • Frequency – 100 Hz or I KHz Automatic
  • Conductivity
    Range-0.1 uS to 100 mS. (6 decadie rzingos)
    Accuracy- ±1% of F.S. l digit
    Resolution- 0.001 us
  • TDS
    Range-
    Accuracy-
  • Temperature
    Range-0° C to 100° C (Auto l Manual)
    Resolution-0.1°C
    Accuracy-+0.2° C ±l digit
  • Cell Constant-Acceptable from 0.1 to 5.0
  • Auto Temp. Compensation-0° C to 100° C with PT l00 sensor
  • Manual Temp. Compensation-0° C to 60° C user selectable
  • Conductivity Temp. Co-efficient-0.0% to 9.9% user selectable
  • Display-7 digits, 7 segment LEDs
    (3 digits for TEMP/TEMPCO
    4 digits for Conductivity)
    With automatic decimal point selection
  • TDS-factor
  • Printer Port -Epson compatible 80 Column Dot Matrix
  • Power-230V AC, ±10%, 50 Hz
  • Dimensions-250(W) X 205(D) X 75(H) mm
    Weight-1.25 Kg (Approx)
  • Accessories-i) Conductivity cell, cell constant 0.1
    ii)Conductivity cell, cell constant 1.0
    iii)Temperature probe (PT-100 sensor)
    iv)Stand & Clamp

Model 307

Specification :

  • Source Frequency– 100Hz or 1KHz automatically selected
  • Conductivity Range -0 pS to 20 mS with 0.1 cell constant and 0 pS to 200 mS with 1 cell (5 decadic ranges)
  • TDS -0ppm to 20 ppt with 0.1 cell constant
    and 0 ppm to 200 ppt with 1 cell constant in 5 decadic ranges
  • Temperature -0° C to 100° C (Manual)
  • Display – 3 digits LED
  • Resolution
    Conductivity
    TDS
    Temperature -0.01is is lowest range with cell constant of 0.1 0.01 ppm in lowest range with cell constant of 0.11° C
  • Accuracy
    Conductivity / TDS
    Temperature – +1% of t.s. +t digi1 +1° C +1 digit
  • Cond.Celt Compensation – 0.09 to 0.11 0.9 to 1.1
  • TDS – Factor – 0 to 1.00
  • Temperature Range – 0.0 to 10.0% per °C  0 to 100° C
  • Temperature Sensor – PT 100
  • Power – 230 V +10% 50 Hz
  • Dimensions – 210(W) X 220(D) X 105(H) mm
  • Weight – 1.7 kg (Approx)
  • Accessories– 1 Cetl Constant Cell
    1 Cell Constant Cell
    Temperature probe (Pt. 100 sensor)
    Clamp & Stand

Model 308

Specification :

  • Frequency – 100 Hz or I KHz Automatic
  • Conductivity
    Range-0.1 uS to 100 mS. (6 decadie rzingos)
    Accuracy- ±1% of F.S. l digit
    Resolution- 0.001 us
  • TDS
    Range-
    Accuracy-
  • Temperature
    Range-0° C to 100° C (Auto l Manual)
    Resolution-0.1°C
    Accuracy-+0.2° C ±l digit
  • Cell Constant-Acceptable from 0.1 to 5.0
  • Auto Temp. Compensation-0° C to 100° C with PT l00 sensor
  • Manual Temp. Compensation-0° C to 60° C user selectable
  • Conductivity Temp. Co-efficient-0.0% to 9.9% user selectable
  • Display-7 digits, 7 segment LEDs
    (3 digits for TEMP/TEMPCO
    4 digits for Conductivity)
    With automatic decimal point selection
  • TDS-factor
  • Printer Port -Epson compatible 80 Column Dot Matrix
  • Power-230V AC, ±10%, 50 Hz
  • Dimensions-250(W) X 205(D) X 75(H) mm
    Weight-1.25 Kg (Approx)
  • Accessories-i) Conductivity cell, cell constant 0.1
    ii)Conductivity cell, cell constant 1.0
    iii)Temperature probe (PT-100 sensor)
    iv)Stand & Clamp