Electronic Balance
- Home
- Weighing Scale
Weighing Scale
Designed with the technology to ensure that your very specific weighing results are accurate and provides an easy yet efficient weighing experience. Easily operatable, fast and stable equipment. Users can choose from options to configure their balance to suit their individual needs and obtain the optimal solution for integration into their process.
Used in Weighing, Percent Weighing, Parts Counting, Check Weighing, Dynamic Weighing, Totalization, Formulation, Differential Weighing, Density Determination, Peak Hold, Pipette Adjustment, SQC, Laboratory, Research.
Also known as Analytical balance, Laboratory Balance, Weighing Balance, Laboratory Weighing Balance.
Model: AP124X
Specification:
- CAPACITY 120G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT INTERNAL
- EXTERNAL CALIBRATION 45 to 120.009 g
- CALIBRATION 100G
- REPEATABILITY 0.1MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.2 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP224X
Specification:
- CAPACITY 220G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT INTERNAL
- EXTERNAL CALIBRATION 95 to 220.009 g
- CALIBRATION 200G
- REPEATABILITY 0.1MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.2 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP324X
Specification:
- CAPACITY 320G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT INTERNAL
- EXTERNAL CALIBRATION 95 to 320.009 g
- CALIBRATION 300G
- REPEATABILITY 0.15MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.3 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP124Y
Specification:
- CAPACITY 120G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT EXTERNAL
- EXTERNAL CALIBRATION 45 to 120.009 g
- CALIBRATION 100G
- REPEATABILITY 0.1MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.2 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP324Y
Specification:
- CAPACITY 320G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT EXTERNAL
- EXTERNAL CALIBRATION 95 to 320.009 g
- CALIBRATION 300G
- REPEATABILITY 0.15MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.3 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP224Y
Specification:
- CAPACITY 220G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT EXTERNAL
- EXTERNAL CALIBRATION 95 to 220.009 g
- CALIBRATION 200G
- REPEATABILITY 0.1MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.2 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: AP224Y
Specification:
- CAPACITY 320G
- MINIMUM DISPLAY 0.1MG
- CALIBRATION WEIGHT INTERNAL
- EXTERNAL CALIBRATION 95 to 320.009 g
- CALIBRATION 300G
- REPEATABILITY 0.15MG
- MINIMUM WEIGHT *1 200MG
- LINEARITY ±0.3 mg
- RESPONSE TIME FOR TRACE MEASUREMENTS *2 2SEC
- RESPONSE TIME *3 2SEC
- OPERATING TEMPERATURE 5 to 40°C
- SENSITIVITY ±2 ppm/°C (10 to 30°C)
- PAN SIZE ø91 mm
Model: ATX84R
Specification:
- Capacity – 82g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration Internal
Model: ATX124R
Specification:
- Capacity – 120g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration Internal
Model: ATX224R
Specification:
- Capacity – 220g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration Internal
Model: ATX324R
Specification:
- Capacity – 320g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration Internal
Model: ATY64R
Specification:
- Capacity – 62g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration External
Model: ATY124R
Specification:
- Capacity – 120g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration External
Model: ATY324R
Specification:
- Capacity – 320g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration External
Model: ATY224R
Specification:
- Capacity – 220g
- Display -0.1mg
- Repeatability -<0.1mg
- Linearity -+/- 0.2mg
- Stabilisation Time*1 -Approx. 3.0 seconds
- Operating Temperature and 5-40°C 20-85%*2
- Humidity Limits
- Temperature Coefficient for ± 2 ppm/ °C
- Sensitivity (10-30°C)
- Pan Size (mm) approx ø91
- Power Requirement 12V, 1A
- Calibration External
Model: UP223X
Specification:
- Capacity 220g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP423X
Specification:
- Capacity 420g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP623X
Specification:
- Capacity 620g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP823X
Specification:
- Capacity 820g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP1023X
Specification:
- Capacity 1020g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP422X
Specification:
- Capacity 420g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP822X
Specification:
- Capacity 820g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration Internal
Model: UP2202X
Specification:
- Capacity 2200g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration Internal
Model: UP4202X
Specification:
- Capacity 4200g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration Internal
Model: UP6202X
Specification:
- Capacity 6200g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration Internal
Model: UP4201X
Specification:
- Capacity 4200g
- Minimum display 0.1g/100mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration Internal
Model: UP8201X
Specification:
- Capacity 8200g
- Minimum display 0.1g/100mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration Internal
Model: UP223Y
Specification:
- Capacity 220g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP423Y
Specification:
- Capacity 420g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP623Y
Specification:
- Capacity 620g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP823Y
Specification:
- Capacity 820g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP1023Y
Specification:
- Capacity 1020g
- Minimum display 0.001g/1mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP422Y
Specification:
- Capacity 420g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 108 x 105 mm
- Calibration External
Model: UP4202Y
Specification:
- Capacity 4200g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration External
Model: UP6202Y
Specification:
- Capacity 6200g
- Minimum display 0.01g/10mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration External
Model: UP4201Y
Specification:
- Capacity 4200g
- Minimum display 0.1g/100mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration External
Model: UP8201Y
Specification:
- Capacity 8200g
- Minimum display 0.1g/100mg
- Repeatability ≦0.001g
- Linearity ± 0.002g
- Response Time Approx. 1 sec.
- Sensitivity Stability ± 3 ppm/°C
- Against Temperature Range (10 to 30°C)
- Pan Size Approx. 170 x 180 mm
- Calibration External
Model: BW12KH
Specification:
- Calibration: Internal
- Display: 100mg/0.1g
- Capacity: 12kg
- Pan Size: 345×250
- Readability (mg): 100
- Stabilization Time (sec):2
- Repeatability (mg):100
- Internal Calibration: Yes
- RS-232:Yes
Model: BW22KH
Specification:
- Calibration: Internal
- Display: 100mg/0.1g
- Capacity: 22kg
- Pan Size: 345×250
- Readability (mg): 100
- Stabilization Time (sec):2
- Repeatability (mg):100
- Internal Calibration: Yes
- RS-232
Model: BW32KH
Specification:
- Calibration: Internal
- Display: 100mg/0.1g
- Capacity: 12kg
- Pan Size: 345×250
- Readability (mg): 100
- Stabilization Time (sec):2
- Repeatability (mg):100
- Internal Calibration: Yes
- RS-232:Yes
Model: BW32KS
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: BW52KS
Specification:
- Calibration: Internal
- Display: 100mg/0.1g
- Capacity: 12kg
- Pan Size: 345×250
- Readability (mg): 100
- Stabilization Time (sec):2
- Repeatability (mg):100
- Internal Calibration: Yes
- RS-232:Yes
Model: BX12KH
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: BX22KH
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: BX32KH
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: BX32KS
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: BX52KS
Specification:
- Windows Direct function
- Superior durability
- Guaranteed sensitivity
- Selectable weighing modes
- Built-in calibration weight (BW-K Series only)
- Analog display modes
- Full range
- Fill-in
- Check weighing
Model: TW223L
Specification:
- Capacity -220g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -Internal
Model: TW323L
Specification:
- Capacity -320g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -Internal
Model: TW423L
Specification:
- Capacity -420g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -Internal
Model: TX223L
Specification:
- Capacity -220g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -External
Model: TX323L
Specification:
- Capacity -320g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -External
Model: TX423L
Specification:
- Capacity -420g
- Minimum Display -0.001g/1mg
- Repeatability -0.001g
- Linearity -+/-0.002g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -External
Model: TX2202L
Specification:
- Capacity -2.2kg
- Minimum Display -0.01g/10mg
- Repeatability -0.01g
- Linearity -+/-0.02g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – 167X181mm
- Power Requirements – 12V, 1A
- Calibration -External
Model: TX3202L
Specification:
- Capacity -3.2kg
- Minimum Display -0.01g/10mg
- Repeatability -0.01g
- Linearity -+/-0.02g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – 167X181mm
- Power Requirements – 12V, 1A
- Calibration -External
Model: TX4202L
Specification:
- Capacity -4.2kg
- Minimum Display -0.01g/10mg
- Repeatability -0.01g
- Linearity -+/-0.02g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-3
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – 167X181mm
- Power Requirements – 12V, 1A
- Calibration -External
Model: TXB622L
Specification:
- Capacity -620g
- Minimum Display -0.01g/10mg
- Repeatability -0.01g
- Linearity -+/-0.02g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-5
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -External
Model: TXB6201L
Specification:
- WindowsDirect Communication Function Only a cable is needed to send weighing data to a computer
- Comparator function
- RS-232C interface
- Expanded Piece Counting function
- Power saving function
- Fast and flexible calibration
- Can be used anywhere with battery power
- Change among many weighing units and functions with a single touch
- Easy Setting
Model: TXB622L
Specification:
- Capacity -620g
- Minimum Display -0.01g/10mg
- Repeatability -0.01g
- Linearity -+/-0.02g
- Operating Ambient Temperature (°C) – 5-40
- Temperature Coefficient – +/-5
- Sensitivity (ppm/ °C) (10–30°C)
- Pan Size (mm) approx. – ø110
- Power Requirements – 12V, 1A
- Calibration -External
Model: TXB6201L
Specification:
- WindowsDirect Communication Function Only a cable is needed to send weighing data to a computer
- Comparator function
- RS-232C interface
- Expanded Piece Counting function
- Power saving function
- Fast and flexible calibration
- Can be used anywhere with battery power
- Change among many weighing units and functions with a single touch
- Easy Setting
Model: ELB300
Specification:
- Capacity -300g
- Minimum Display -0.01g/10mg
- Taring range -0g to capacity
- Operating Ambient Temperature (°C) – 5-35
- Pan Size (mm) approx. – ø110
- Calibration -External
Model: ELB3000
Specification:
- Capacity -3kg
- Minimum Display -0.1g/100mg
- Taring range -0g to capacity
- Operating Ambient Temperature (°C) – 5-35
- Pan Size (mm) approx. – 170 X 130
- Calibration -External
Model: ELB12KH
Specification:
- Capacity -12kg
- Minimum Display -1g/1000mg
- Taring range -0g to capacity
- Operating Ambient Temperature (°C) – 5-35
- Pan Size (mm) approx. – 170 X 130
- Calibration -External
Model: AP225WD
Specification:
- Capacity 220 g / 102 g
- Minimum Display 0.01 mg / 0.1 mg
- Calibration Weight Internal
- External Calibration Weight Range for Span 95 to220.0090 g
- Calibration 100g
- Repeatability (Standard deviation) 0.1 mg / 0.05 mg
Model: AP125WD
Specification:
- Capacity 120 g / 52 g
- Minimum Display 0.01 mg / 0.1 mg
- Calibration Weight Internal
- External Calibration Weight Range for Span 45 to 120.0090 g
- Calibration 100g
- Repeatability (Standard deviation) 0.1 mg / 0.02 mg
- Repeatability (for Low Loads) 0.015 mg
- Minimum Weight *1 30g
- Linearity ±0.2 mg /±0.05 mg
- Response Time for Trace Measurements *2 2 sec.
- Response Time *3 2 sec. / 8 sec.
- Operating Temperature/Humidity Range 5 to 40°C 20 to 85% *4
- Sensitivity Stability Against Temperature Range ±2 ppm/°C (10 to 30°C)
- Pan Size ø91 mm
- Display OEL display (dot matrix)
- USB Host (Type A)
- USB Device (Type B)
- Recipe Compounding
- HPLC Buffer Solution Preparation
- mol Conversion Function
- Sample (Concentration) Preparation
- Inspection Support Function
- Clock-CAL
- Ionizer