Electrophoresis
- Home
- Power Pack
Power Pack
This electrophoresis power supply is recommended for basic applications such as submerged horizontal and mini vertical gel electrophoresis. It offers timer control and constant-voltage or constant-current output.
Power Pac Basic
Model : 164 5050
Specifications:
Output range (programmable)
10–300 V, fully adjustable in 1 V steps
4–400 mA, fully adjustable in 1 mA steps75 W (maximum)
10–300 V, fully adjustable in 1 V steps
4–400 mA, fully adjustable in 1 mA steps75 W (maximum)
Type of output
Constant voltage or constant current with automatic crossover
Constant voltage or constant current with automatic crossover
Output terminals
4 pair recessed banana jacks in parallel
4 pair recessed banana jacks in parallel
Timer
1 min–99 hr 59 min, fully adjustable
1 min–99 hr 59 min, fully adjustable
Pause/resume function
Yes
Yes
Display
3-digit LED
3-digit LED
Operating conditions
0–40°C, 0–95% humidity in the absence of condensation
0–40°C, 0–95% humidity in the absence of condensation
Regulatory
EN-61010, CE
EN-61010, CE
Safety features
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
Input protection
Fuse on both hot and neutral
Fuse on both hot and neutral
Input power
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
Power Pac HC
Model : 164 5052
Specifications:
Output range (programmable)
5–250 V
0.01–3.0 A
1–300 W
5–250 V
0.01–3.0 A
1–300 W
Timer
1 min–99 hr, 59 min
1 min–99 hr, 59 min
Pause/resume function
Yes
Yes
Display
16-character x 2-line LCD
16-character x 2-line LCD
Programmable Methods
1 method up to 3 steps, no storage capability
1 method up to 3 steps, no storage capability
Safety features
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
Input protection
Fuse on both hot and neutral
Fuse on both hot and neutral
Input power
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
Power Pac HV
Model : 164-5056
Specifications:
Output range (programmable)
20–5,000 V
0.01–500 mA
1–400 W
0.01–500 mA
1–400 W
Type of output
Constant voltage, constant current, constant power, or constant temperature
Constant voltage, constant current, constant power, or constant temperature
Timer
1 min–99 hr, 59 min
1 min–99 hr, 59 min
Pause/resume function
Yes
Yes
Display
128 x 64 pixel, backlit graphics LCD
128 x 64 pixel, backlit graphics LCD
Programmable Methods
Stores 9 methods, each with up to 9 steps
Stores 9 methods, each with up to 9 steps
Safety features
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
Input protection
Fuse on both hot and neutral
Fuse on both hot and neutral
Input power
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
Power Pac Universal
Model : 164 5070
Specifications:
Output range (programmable)
10–500 V
0.01–2.5 A
1–500 W
0.01–2.5 A
1–500 W
Type of output
Constant voltage, constant current, or constant power
Constant voltage, constant current, or constant power
Timer
1 min–99 hr, 59 min
1 min–99 hr, 59 min
Pause/resume function
Yes
Yes
Display
128 x 64 pixel, backlit graphics LCD
128 x 64 pixel, backlit graphics LCD
Programmable Methods
Stores 9 methods, each with up to 9 steps
Stores 9 methods, each with up to 9 steps
Safety features
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
No-load detection, sudden load change detection, overload/short-circuit detection, overvoltage protection
Input protection
Fuse on both hot and neutral
Fuse on both hot and neutral
Input power
90–120 or 198–264 VAC, 50/60 Hz, autoswitching
90–120 or 198–264 VAC, 50/60 Hz, autoswitching